Span (inches)

CONCENTRATED LOAD in lb/ft of width

Max
Load (lb/ft)

Apparent
EI x 106
(lb-in2)

50

100

150

200

250

500

1000

2000

12

0.002

0.004

0.006

0.008

0.009

0.019

0.038

0.075

5112

0.96

18

0.005

0.010

0.015

0.020

0.025

0.050

0.100

0.199

3408

1.22

24

0.011

0.022

0.033

0.044

0.055

0.109

0.218

0.436

2556

1.32

30

0.021

0.041

0.062

0.083

0.103

0.207

0.414

2045

1.36

36

0.035

0.070

0.106

0.141

0.176

0.352

1704

1.38

42

0.055

0.110

0.165

0.221

0.276

0.551

1461

1.40

48

0.081

0.162

0.243

0.325

0.406

1278

1.42

Span (inches)

UNIFORM LOAD in lb/ft2

Max
Load (lb/ft2)

Apparent
EI x 106
(lb-in2)

50

100

150

200

250

500

1000

2000

12

0.001

0.002

0.004

0.005

0.006

0.012

0.023

0.047

10418

0.96

18

0.005

0.009

0.014

0.019

0.023

0.047

0.093

0.187

4562

1.22

24

0.014

0.027

0.041

0.055

0.068

0.136

0.273

0.545

2582

1.32

30

0.032

0.065

0.097

0.129

0.162

0.323

0.646

1626

1.36

36

0.066

0.132

0.198

0.264

0.330

0.660

1137

1.38

42

0.121

0.241

0.362

0.482

0.603

835

1.40

48

0.203

0.406

0.608

638

1.42

Properties Per Foot of Width

# of Bars

Load Bar Depth

Bar Centers

Weight/sq ft

A = 2.86 in2 I = 0.37 in4 ST = 1.00 in3 SB = 0.59 in3

6

1″

2″

2.39

Technical illustrations of concentrated load and uniform load for PROGrate Fiberglass Reinforced Plastic grating.1. Tables were developed in accordance with the test method developed by the Fiberglass Grating Manufacturers Council (FGMC) of the American Composites Manufacturers Association (ACMA) for the Fiberglass Grating Standard.

2. The designer should not exceed MAXIMUM RECOMMENDED load at any time. ULTIMATE CAPACITY represents MAX LOAD observed at initial fracture.

3. Walking loads for maintenance traffic are typically a live load of 50 PSF. Deflections for worker comfort are typically limited to 0.375″ (3/8″) or SPAN divided by 120 under full live load. For a firmer feel under full live load or a line load 250 lb/ft of width, limit deflections to 0.25″ (1/4″) or SPAN divided by 200.

4. The loads represented are for STATIC LOAD CONDITIONS at ambient temperature. Deflections for impact loads or dynamic loads will MULTIPLY the deflections shown by 2. Long term loads will result in added deflection due to creep in the material and will require higher factors of safety to ensure acceptable performance.

5. Deflections are limited too 0.5″ (1/2″) as recommended by the Fiberglass Grating Manufacturers Council of the American Composites Manufacturers Association.

Technical illustration of Fiberglass Reinforced Plastic T bearing bar grating, 10-18 VGBA certified.